Understanding the Options:
Vaccines - Mammalian Cell
Cell Harvesting
Essential Process Requirements
(In place of TFF/Centrifuge, post fermentation)- Remove heavy solid loads from bioreactor fluid and recover product in filtrate
- Requires high capacity
- Wide feed stream variability depending on cell culture type and conditions
- If solid content is too high, centrifugation becomes preferred technology
| Recommended Filter | Filter Characteristics |
Prostak Open-Channel Modules with Durapore 0.22 µm Membrane |
|
Double-layer Millistak+ HC Filters (Grade D0HC or C0HC) Disc Filters Pod Filters |
|
ALTERNATIVE: For smaller batch sizes where no centrifuge or TFF step is required Millipore suggests using Clarigard 0.3 µm or Double-layer Milligard 0.5 µm + 0.2 µm (Grade SS) Filters in your process. Choice should be based on small-scale testing.
Clarification or Polishing (Post TFF or Centrifuge)
Essential Process Requirements
- Remove cell debris, small particles and colloids passed through the primary clarification step
- Potential for variations in fluid particle size distribution
- Must have high capacity and protect downstream sterilizing-grade filters
| Recommended Filter | Filter Characteristics |
Triple-layer Millistak+ HC Filters (Grade B1HC) Disc Filters Pod Filters |
|
Double-layer Milligard Filters (Grade SS, 0.5 µm + 0.2 µm) Cartridge Filters Opticap Capsule Filters Optiscale Capsule Filters |
|
Bioburden Reduction
Essential Process Requirements
- Reduces bioburden at intermediate process step
- Protects downstream filters, media and equipment
- Preserves product purity
- Sterilizing-grade filtration required
| Recommended Filter | Filter Characteristics |
Double-layer Millipore Express SHC 0.5 µm + 0.2 µm Filters Cartridge Filters Opticap Capsules |
|
Concentration and Diafiltration (Prior to column chromatography steps)
Essential Process Requirements
- Concentration of process fluids and buffer exchange
- Will extend the life of expensive chromatography media and improve their speed and efficiency
- Fast, robust process able to accommodate feed fluid variations
- Wide chemical compatibility with cleaning agents
- Easily scalable from lab to manufacturing scale
| Recommended Filter | Filter Characteristics |
Pellicon C Screen Cassettes with Ultracel PLC 100, 300 or 1,000 kD Membrane |
|
Concentration and Diafiltration (For final formulation)
Essential Process Requirements
- Concentration and diafiltration adjusts the end product to the proper dosage conditions prior to final packaging
- Fast, robust process able to accommodate feed fluid variations
- Easily scalable from lab to manufacturing scale
| Recommended Filter | Filter Characteristics |
Pellicon C Screen Cassettes with Ultracel PLC 100 or 300 kD Membrane |
|
Sterile Filtration
Essential Process Requirements
- Sterilizing-grade step to reduce bioburden or sterilize heat labile products
- Highly validated and reliable technology
- Preserves product purity
- Ensures product safety
| Recommended Filter | Filter Characteristics |
Durapore 0.22 µm Filters Cartridge Filters Optiseal Cartridge Filters Opticap Capsule Filters Optiseal Capsule Fitlers |
|
Product News & Releases
- Millipore Introduces Solvex™ Solvent Filters - New cartridge filters ideal for sterile manufacture of APIs