Aerex Cartridge Filter
Description:
Aerex CTGB Cartridge Filter 10 in. 0.2 µm Code 5
Trade Name:
Aerex
Qty/Pk:
3
Nitrogen Diffusion at 23 °C:
≤15 mL/min @ 690 mbar (10 psig) in 60/40 % IPA/water
Filtration Area, m²:
0.65
Maximum Differential Pressure, bar (psid):
Forward: 6.9 (100) @ 25 °C; 1.7 (25) @ 80 °C; 0.35 (5) @ 145 °C. Reverse: 5.2 (75) @ 25 °C, intermittent
Diameter, cm (in):
6.9 (2.7)
Bubble Point at 23 °C:
≥900 mbar (13 psig) nitrogen with 60/40 % IPA/water
Cartridge Nominal Length, in (cm):
10 (25)
Pore Size (µm):
0.2
Wettability:
Hydrophobic
Sterilization:
200 (150 forward/50 reverse) SIP cycles of 30 min @ 145 °C; SIP up to 165 hours in forward direction @ 145 °C
HydroCorr:
≤0.40 mL/min per 10-inch cartridge with water @ 1380 mbar (20 psig)
Good Manufacturing Practices:
This product was manufactured in a facility which adheres to Good Manufacturing Practices.
Gravimetric Extractables:
The extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
Product Name:
Aerex Cartridge Filter
Non-Fiber Releasing:
This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Bacterial Endotoxins:
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Grow-Through:
The membrane has been qualified to retain bacteria when challenged for 21 days with a minimum Brevundimonas diminuta aerosol concentration of 1 x 10⁷ CFU/cm².
Device Material:
Polypropylene
Configuration:
Cartridge
Chemistry:
Hydrophobic PTFE
Cartridge Code:
Code 5 (2-222) O-rings and spear
Media:
Aerex
Support Material:
Polypropylene
Packaging:
Double Easy-Open bag
Code:
Code 5
Seal Material:
Silicone
Device Size (in):
10