Durapore Cartridge Filter
Description:
Durapore Cartridge Filter 30 in. 0.1 µm Code 0
Trade Name:
Durapore
Key Applications:
Laboratory Filtration
Support Material:
Polypropylene
Air Diffusion at 23 °C:
≤60 mL/min @ 3.9 bar (56 psig) in water
Diameter, cm (in):
6.9 (2.7)
Packaging:
Double Easy-Open bag
Filtration Area, m2:
2.07
Configuration:
Cartridge Filter
Cartridge Type:
Liquid
Gravimetric Extractables:
≤60 mg after 24-h soak in water
Filter Brand Name:
Durapore
Bubble Point at 23 °C:
≥4830 mbar (70 psig) air with water
Bacterial Retention:
Quantitative retention of 107 CFU/cm2 Brevundimonas diminuta (ATCC® 19146) per ASTM F838-83 methodology
Cartridge Code:
Code 0 (2-222) O-rings
Wettability:
Hydrophilic
Cartridge Nominal Length, in (cm):
30 (75)
Maximum Differential Pressure, bar (psid):
Forward: 5.5 (80) @ 25 °C; 1.7 (25) @ 80 °C; 0.35 (5) @ 135 °C. Reverse: 3.5 (50) @ 25 °C
Filter Pore Size, µm:
0.1
Seal Material:
Silicone
Bacterial Endotoxins:
<0.5 EU/mL as determined by the LAL test
Filter Material:
Hydrophilic PVDF
Oxidizable Substances:
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≤3 L
Sterilization:
30 SIP cycles of 30 min @ 135 °C; 30 autoclave cycles of 60 min @ 126 °C
Device Material:
Polypropylene
Flow Rate, L/min:
15 @ 230 mbar P