Opticap XL Capsule Filter

Recommended Replacement for: SN2M027A6

Description:
Opticap XL10 Aervent 0.2 µm 1-1/2 in. TC/TC
Trade Name:
Opticap
Key Applications:
Laboratory Filtration
Support Material:
Polypropylene
Diameter, cm (in):
14.5 (5.7)
Housing:
Polypropylene
Sterility:
Non-Sterile
Packaging:
Double Easy-Open bag
Filtration Area, m2:
0.65
Configuration:
Capsule Filter
Vent Cap Material:
Polypropylene
Gravimetric Extractables:
≤45 mg in 70//30 % IPA/water
Filter Brand Name:
Aervent
Bubble Point at 23 °C:
≥1100 mbar (16 psig) nitrogen with 70//30 % IPA/water
Bacterial Retention:
Quantitative retention of 107 CFU/cm2 Brevundimonas diminuta (ATCC® 19146) per ASTM F838-83 methodology
Maximum Inlet Pressure, bar (psi):
5.5 (80) @ 25 °C; 2.75 (40) @ 60 °C; 1.0 (15) @ 80 °C
Connections, Inlet/Outlet:
38 mm (1-1/2 in.) Sanitary Flange
Wettability:
Hydrophobic
Filter Pore Size, µm:
0.2
Maximum Differential Pressure, bar (psid):
Forward: 5.5 (80) @ 25 °C; 1.0 (15) @ 80 °C. Reverse: 4.1 (60) @ 25 °C, intermittent
Seal Material:
Silicone
Capsule Type:
Liquid
Bacterial Endotoxins:
<0.5 EU/mL as determined by the LAL test
Filter Material:
Hydrophobic PTFE
Replaces:
SN2M027A6
HydroCorr Test:
≤0.75 mL/min @ 2.6 bar (38 psig)
Connections, Vent/Drain:
1/4 in. Hose Barb with double O-ring Seal
Length, cm (in):
33.5 (13.2)
Device Material:
Polypropylene
Sterilization:
30 autoclave cycles of 30 min @ 135 °C; not in-line steam sterilizable
Nitrogen Diffusion at 23 °C:
≤10 mL/min @ 1.7 bar (25 psig) in water