MILLIPLEX MAP Human Kidney Toxicity Magnetic Bead Panel 4
Trade Name:
MILLIPLEX
Qty/Pk:
96-well plate
Background Information:
Absorption, distribution, metabolism and excretion (ADME) calculations are critical to all stages of a fully integrated drug development program and are used to augment the interpretation of toxicological findings. As toxicity has been found to be the leading cause of drug failure, this area of research is expanding in search of more sensitive, rapid methods for determining damage as quickly as possible. Renal toxicity, or drug induced damage to kidney cells, can result from drug excretion. The traditional methodology for determining renal toxicity has been to use the blood urea nitrogen (BUN) and serum creatinine. These two tests do not detect localized damage. Consequently, Millipore’s MILLIPLEXⓇ Human Kidney Magnetic Bead Panel 4 offers the advantage of speed and sensitivity, allowing quantitative multiplex detection of multiple analytes.
Applications:
This MILLIPLEX® MAP Human Kidney Toxicity Magnetic Bead Panel 4 is a Toxicity multiplex assay. The analytes available for this multiplex kit are: Albumin, β-2-Microglobulin, Clusterin, Cystatin C, OPN - Osteopontin.
Key Applications:
Multiplexing
Application Notes:
25 µl diluted urine
Overnight assay
Overnight assay
Species Reactivity:
Human
Usage Statement:
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Configuration:
Design your multiplex kit by choosing from 5 analytes.
Sensitivity:
- Albumin: 933 pg/mL
- β-2-Microglobulin: 54 pg/mL
- Clusterin: 905 pg/mL
- Cystatin C: 114 pg/mL
- OPN: 176 pg/mL
Panel Type:
MAGNETIC Kidney Toxicity
Precision, %:
- Inter-assay: 3-15%
- Intra-assay: 4-16%
Accuracy:
- Albumin 108%
- β-2-Microglobulin 124%
- Clusterin 127%
- Cystatin C 82%
- OPN 95%
Detection Methods:
Luminex xMAP
Replaces:
This product replaces Human Kidney Toxicity Panel 4, HKTX4-38K in December of 2011 or while supplies last.
Cross Reactivity:
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Product Name:
MILLIPLEX MAP Human Kidney Toxicity Magnetic Bead Panel 4
Standard Curve Range:
- Albumin: 977-1,000,000 pg/mL
- β-2-Microglobulin: 49-50,000 pg/mL
- Clusterin: 1,953-2,000,000 pg/mL
- Cystatin C: 98-100,000 pg/mL
- OPN: 195-200,000 pg/mL
Analytes Available:
Albumin, Clusterin, Cystatin C, OPN - Osteopontin, β-2-Microglobulin