Lifegard Cartridge Filters

Description

Lifegard glass microfiber medium was designed for removal of deformable and non-deformable particles and microorganisms from liquids. Versatile depth-type products retain contaminants within the matrix of glass microfiber medium. The Lifegard media is used to achieve exceptional retention efficiency. Because of its high holding capacity, adsorptive removal properties and excellent wet strength, it is very well-suited for the clarification and prefiltration of serum, plasma proteins, gene therapy and other viscous biologicals.

Lifegard cartridge filters are ideally suited for processes that require maximum pressure differentials. Cartridges are robust, strong, resilient and are designed to withstand multiple steam-in-place cycles.

Regulatory Compliance

Filters with Lifegard media are designed, developed, and manufactured in accordance with a Quality Management System approved by an accredited registering body to an ISO® 9000 Quality Systems Standard and are shipped with a Certificate of Quality for documentation accuracy. Each cartridge filter is supported by a Validation Guide for compliance with regulatory requirements.

For traceability and easy identification, each filter is marked with identifying characteristics.

Multiple Formats Available

A full range of filtration areas is available to suit your application requirements. A variety of connection options are offered for easy adaptation to existing housings.

The Filter of Choice in Plasma Proteins and Serum Applications

Lifegard filters protect downstream sterile filters and chromatography columns while effectively removing contaminants and retaining valuable fractions of interest. These filters will remove colloids, aggregated and non-product proteins, lipids and other particles before downstream purification.

Specifications (return to top)

Per 10-inch Cartridge Filter
Materials of Construction
Filter MediaBorosilicate Glass Fiber
SupportsPolypropylene
Structural ComponentsPolypropylene
O-ringsSilicone
Filtration Area, m20.46
Maximum Differential Pressure, bar (psid)3.5 (50) @ 25 °C
Bacterial Endotoxins<1 EU/mL as determined by the LAL test
Gravimetric Extractables≤250 mg after 24-h soak in water and 5 L flush
Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of 5 L
Component Material ToxicityComponent materials meet the criteria of the USP <88> Reactivity Test for Class VI Plastics. These products meet the requirements of the USP <88> Safety Test, utilizing a 0.9% sodium chloride extraction.
Sterilization10 autoclave cycles or SIP @ 121 °C for 30 min
Sanitization30 min with hot water @ 80 °C
Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Device Good Manufacturing Practices.
Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177–182.

Typical Clean Water Flow Rate vs Pressure Drop

CPX10-41[8881-ALL].jpg

10-inch Cartridge Filters with Lifegard Media — 1.0 and 2.0 µm Nominal


订购信息  回到页首

Select up to 5 products to compare them side by side
Code 0 2-222 O-ring

比较 目录编号 标称孔径,µm 标称长度,in (cm)  
CP1501S03 1 10 (25) » 添加到购物车
CP1502S03 1 20 (50) » 添加到购物车
CP1503S03 1 30 (75) » 添加到购物车
CP1504S03 1 40 (100) » 添加到购物车
CP2001S03 2 10 (25) » 添加到购物车
CP2002S03 2 20 (50) » 添加到购物车
CP2003S03 2 30 (75) » 添加到购物车
CP2004S03 2 40 (100) » 添加到购物车
To order cartridges with other o-ring material than the standard silicone, replace the 7th digit by E for ethylene-propylene or V for fluoroelastomer.
Packaged 3 cartridges per box
Code 5 2-222 O-ring w/spear

比较 目录编号 标称孔径,µm 标称长度,in (cm)  
CP1551S03 1 10 (25) » 添加到购物车
CP1552S03 1 20 (50) » 添加到购物车
CP1553S03 1 30 (75) » 添加到购物车
CP1554S03 1 40 (100) » 添加到购物车
CP2051S03 2 10 (25) » 添加到购物车
CP2052S03 2 20 (50) » 添加到购物车
CP2053S03 2 30 (75) » 添加到购物车
CP2054S03 2 40 (100) » 添加到购物车
To order cartridges with other o-ring material than the standard silicone, replace the 7th digit by E for ethylene-propylene or V for fluoroelastomer.
Packaged 3 cartridges per box
Code 7 2-226 O-ring w/locking-tabs and spear

比较 目录编号 标称孔径,µm 标称长度,in (cm)  
CP1571S03 1 10 (25) » 添加到购物车
CP1572S03 1 20 (50) » 添加到购物车
CP1573S03 1 30 (75) » 添加到购物车
CP1574S03 1 40 (100) » 添加到购物车
CP2071S03 2 10 (25) » 添加到购物车
CP2072S03 2 20 (50) » 添加到购物车
CP2073S03 2 30 (75) » 添加到购物车
CP2074S03 2 40 (100) » 添加到购物车
To order cartridges with other o-ring material than the standard silicone, replace the 7th digit by E for ethylene-propylene or V for fluoroelastomer.
Packaged 3 cartridges per box
Code F Double Open End Flat Gaskets

比较 目录编号 标称孔径,µm 标称长度,in (cm)  
CP15F1E03 1 10 (25) » 添加到购物车
CP15F2E03 1 20 (50) » 添加到购物车
CP15F3E03 1 30 (75) » 添加到购物车
CP15F4E03 1 40 (100) » 添加到购物车
CP20F1E03 2 10 (25) » 添加到购物车
CP20F2E03 2 20 (50) » 添加到购物车
CP20F3E03 2 30 (75) » 添加到购物车
CP20F4E03 2 40 (100) » 添加到购物车
Packaged 3 cartridges per box
Code M 2-118 O-ring

比较 目录编号 标称孔径,µm 标称长度,in (cm)  
CP15M4S03 1 4 (10) » 添加到购物车
CP20M4S03 2 4 (10) » 添加到购物车
To order cartridges with other o-ring material than the standard silicone, replace the 7th digit by E for ethylene-propylene or V for fluoroelastomer.
Packaged 3 cartridges per box
Code N 2-226 O-ring

比较 目录编号 标称孔径,µm 标称长度,in (cm)  
CP15N4S03 1 4 (10) » 添加到购物车
CP20N4S03 2 4 (10) » 添加到购物车
To order cartridges with other o-ring material than the standard silicone, replace the 7th digit by E for ethylene-propylene or V for fluoroelastomer.
Packaged 3 cartridges per box


相关产品  回到页首
OptiScale Capsule Filters for Clarification and Prefiltration Applications
OptiScale capsules are a family of convenient, disposable filters ideal for media selection, process screening and scaling. These “drop-in” filter devices, with a variety of media options, create an effective platform for rapidly evaluating biopharmaceuticals. OptiScale offers speed-to-market strategies for efficiently developing compounds and biotherapeutics.
» 更多信息...
Opticap XL Disposable Capsule Filters with Lifegard Media
Superior filters for the clarification and prefiltration of viscous biological fluids when high contaminant holding capacity is required.

The unique capsule design with pleated Lifegard media minimizes hold-up volume and reduces production losses.
» 更多信息...