Aerex Hydrophobic Cartridge Filters

Description

Aerex® hydrophobic cartridges are sterilizing-grade filters manufactured from PTFE membrane and polypropylene components for broad chemical compatibility and low gravimetric extractables. Cartridges are 100% integrity tested during manufacturing to guarantee filter integrity and sterility assurance. The Aerex filter production process has been validated and the manufacturing plant meets ISO® 9001 standards.

Millipore's qualification of Aerex membrane filters includes a challenge regime designed to test virus and bacterial retention by three challenge mechanisms: aerosol, and grow through. Aerex filters have been validated to withstand at least 150 steam cycles at 145 °C, the equivalent of over two years use.

Typical Applications

Aerex hydrophobic cartridges will remove particles and microorganisms from gases and solvents. In gases this filter will remove contamination down to 0.01 µm.

       • Sterile tank venting
       • Fermentation air applications
       • Bioreactor inlet and outlet filtration
       • Autoclaves
       • Sterile process gases


Cartridges will also sterilize alcohol streams.

Specifications (return to top)

per 10-inch Cartridge
Materials of Construction
Filter MembraneHydrophobic PTFE
Structural ComponentsPolypropylene
Filter SupportsPolypropylene
O-ringsSilicone
Filter Pore Size, µm0.2
Filtration Area, m20.65
Maximum Differential Pressure, bar (psid)Forward: 6.9 (100) @ 25 °C; 1.7 (25) @ 80 °C; 0.35 (5) @ 145 °C. Reverse: 5.2 (75) @ 25 °C, intermittent
Integrity Testing
Bubble Point at 23 °C≥900 mbar (13 psig) nitrogen with 60//40 % IPA/water
Air Diffusion at 23 °C≤15 mL/min @ 690 mbar (10 psig) in 60//40 % IPA/water
HydroCorr Test≤0.40 mL/min per 10-inch cartridge with water @ 1380 mbar (20 psig)
Viral RetentionRated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.
Bacterial Aerosol GrowthRetains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 107 CFU/cm2.
Sterilization208 (150 forward/50 reverse) SIP cycles of 30 min @ 145 °C; SIP up to `65 hours in forward direction @ 145 °C
Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Device Good Manufacturing Practices.
Non-fiber ReleasingComponent materials meet the "non-fiber releasing" criteria as defined in 21 CFR 210.3 (b) (6).
Component Material ToxicityComponent materials meet the criteria of the USP <88> Reactivity Test for Class VI Plastics. These products meet the requirements of the USP <88> Safety Test, utilizing a 0.9% sodium chloride extraction.
Certificate of QualityEach cartridge is shipped with a Certificate of Quality which summarizes our stringent manufacturing and quality standards.

Service Life

MB1052-41[131-ALL].jpg

Typical Air Flow Rate vs Pressure Drop at 25 °C

MB4482-41[164-ALL].jpg

10-inch Cartridge

CT0507-41[96-EN].jpg

5-inch Cartridge with 0.2 µm Aervent Membrane—Code 7

CT1005-41[97-EN].jpg

10-inch Cartridge with 0.2 µm Aervent Membrane—Code 0 and 5

CT1007-41[98-EN].jpg

10-inch Cartridge Filter, Code 7

CT2005-41[99-EN].jpg

20-inch Cartridge with 0.2 µm Aervent Membrane—Code 0 and 5

CT2007-41[100-EN].jpg

20-inch Cartridge with 0.2 µm Aervent Membrane—Code 7

CT3005-41[101-EN].jpg

30-inch Cartridge with 0.2 µm Aervent Membrane—Code 0 and 5

CT3007-41[102-EN].jpg

30-inch Cartridge with 0.2 µm Aervent Membrane—Code 7

CT4005-41[103-EN].jpg

40-inch Cartridge with 0.2 µm Aervent Membrane—Code 0 and 5

CT4007-41[104-EN].jpg

40-inch Cartridge with 0.2 µm Aervent Membrane—Code 7


订购信息  回到页首

Select up to 5 products to compare them side by side
Code 0 2-222 O-ring

比较 目录编号 滤膜孔径,µm 标称长度,in (cm)  
CTGB01TP3 0.2 10 (25) » 添加到购物车
CTGB02TP3 0.2 20 (50) » 添加到购物车
CTGB03TP3 0.2 30 (75) » 添加到购物车
CTGB04TP3 0.2 40 (100) » 添加到购物车
Packaged 3 cartridges per box
Code 5 2-222 O-ring w/spear

比较 目录编号 滤膜孔径,µm 标称长度,in (cm)  
CTGB51TP3 0.2 10 (25) » 添加到购物车
CTGB52TP3 0.2 20 (50) » 添加到购物车
CTGB53TP3 0.2 30 (75) » 添加到购物车
CTGB54TP3 0.2 40 (100) » 添加到购物车
Packaged 3 cartridges per box
Code 7 2-226 O-ring w/locking-tabs and spear

比较 目录编号 滤膜孔径,µm 标称长度,in (cm)  
CTGB71TP3 0.2 10 (25) » 添加到购物车
CTGB72TP3 0.2 20 (50) » 添加到购物车
CTGB73TP3 0.2 30 (75) » 添加到购物车
CTGB74TP3 0.2 40 (100) » 添加到购物车
Packaged 3 cartridges per box


相关产品  回到页首
Integritest Mini II P Automatic Filter Integrity Test Instrument
The Integritest Mini II P is a microprocessor-driven portable unit designed to perform a pressure-hold integrity test on membrane filter cartridges.
» 更多信息...
Gasliner Cartridge Housings
The Gasliner 316L stainless steel filter housings are designed for all applications where gas stream needs to be sterilised. This range has been developed to insure a safe protection of both the product and the environment in critical fermentation processes.
» 更多信息...