Millipore’s Reagents for Western Blotting

For simple, cost-effective protein detection, use Millipore's Western blotting reagents to achieve the highest sensitivity with the least background.

Bløk™ Noise Cancelling Reagents

Bløk reagents minimize background in Western blots, increasing sensitivity for superior detection of even low-abundance proteins. Bløk reagents are protein-free, which reduces non-specific binding, especially when you are using phosphoantibodies or avidin-biotin systems.

While Bløk reagents were specially engineered for Millipore’s SNAP i.d. detection system, they can be used to reduce background in traditional Western blotting protocols.

Choose from 3 Bløk reagents

  • • Bløk-CH buffer for HRP chemiluminescence or chromogenic detection
  • • Bløk-FL buffer for fluorescence detection
  • • Bløk-PO buffer for phosphotyrosine detection using chemiluminescence or fluorescence

blok-71[84902-ALL].jpg

Bløk Buffer Features:

  • • Ready-to-use
  • • Protein-free
  • • Will pass freely through SNAP i.d. blot holders
  • • Can be stored at room temperature
  • • Long shelf life:
  •       • Bløk-CH/FL 2 year shelf-life
  •       • Bløk-PO 1 year shelf-life
  • • Available in 500 mL bottle
  • • Compatible with PVDF (Immobilon P, Immobilon FL) and nitrocellulose
  • • Bløk-CH reagent compatible with Immobilon HRP substrate
  • • Compatible with streptavidin antibodies
  • • Ability to dilute the 1° and 2° antibodies using Bløk reagents
  • • Sufficient reagent for 19 mini blots (each 8 x 7 cm blot requires at least 26 mL for SNAP i.d.)

Why use a synthetic blocker?

  • • Reduce cross-reactivity which may be observed with protein-based buffers
  • • Reduce background, especially for detecting low-abundance proteins
  • • If you are studying protein phosphorylation
  • • If you are using an avidin-biotin system

Simplify troubleshooting

Bløk reagents allow you to stain the membrane after immunodetection so you can see if there were problems with the protein transfer, or learn whether each lane contained the same amount of protein.

Immobilion® Western HRP and AP Chemiluminescent Substrates

Millipore’s HRP and AP substrates excel in all Western and dot/slot/spot blotting applications. In addition, they are compatible with both PVDF and nitrocellulose membranes, as well as all commonly used buffers and blocking reagents.

In addition, they give you high sensitivity over a broad detection range at a much lower cost than other chemiluminescent substrates. This combination of versatility and value makes them the only substrates you need for your Western blotting experiments!

Spray and Glow Detection Reagent

The Visualizer™ Spray & Glow™ system is a light-emitting non-radioactive method for detecting immobilized specific antigens in chemiluminescent Western blots through HRP-labeled antibodies. Spray & Glow is comparable in sensitivity to an everyday “workhorse” ECL detection reagent, suitable for normal to high abundance proteins. As a plus, Spray & Glow is easy to use and requires no mixing or pipetting!

Its low background, high signal-to-noise ratio make it ideal for your research. As you may know, low background blots are considered higher quality data that are easier to analyze and more likely to be accepted for publication.


Bestellinformationen  (zurück nach oben)

Bitte wählen Sie höchstens 5 Produkte für den Vergleich.
Bløk™ Noise Cancelling Reagents

Vergleichen Bestellnummer Beschreibung St./Pkg.  
WBAVDCH01 Bløk - CH Noise Cancelling Reagents for Chemiluminescence Detection, 500 mL 1 » In die Bestellung aufnehmen
WBAVDFL01 Bløk - FL Noise Cancelling Reagents for Fluorescent Detection, 500 mL 1 » In die Bestellung aufnehmen
WBAVDP001 Bløk - PO Noise Cancelling Reagents for Phosphoprotein Detection using Chemiluminescence or Fluorescence techniques, 500 mL 1 » In die Bestellung aufnehmen
Immobilon Western Chemiluminescent HRP Substrate

Vergleichen Bestellnummer Beschreibung Reagenzien (Volumina) Membranfläche, cm2  
WBKLS0050 Immobilon Western HRP Substrat, 50 ml Luminol (25 ml); Peroxid-Lösung (25 ml) 500 » In die Bestellung aufnehmen
WBKLS0100 Immobilon Western HRP Substrat, 100 ml Luminol (50 ml); Peroxid-Lösung (50 ml) 1000 » In die Bestellung aufnehmen
WBKLS0500 Immobilon Western HRP Substrat, 500 ml Luminol (250 ml); Peroxid-Lösung (250 ml) 5000 » In die Bestellung aufnehmen
Immobilon Western AP Substrate

Vergleichen Bestellnummer Beschreibung Membranfläche, cm2  
WBKDS0025 Immobilon Western AP Substrat, 25 ml 500 » In die Bestellung aufnehmen
WBKDS0100 Immobilon Western AP Substrat, 100 ml 2000 » In die Bestellung aufnehmen
Visualizer™ Spray & Glow™ ECL Western Blotting Detection System

Vergleichen Bestellnummer Beschreibung St./Pkg.  
17-373 Visualizer™ Spray & Glow™ ECL Western Blotting Detection System 100 mL » In die Bestellung aufnehmen
17-373SP Visualizer™ Spray & Glow™ ECL Western Blotting Detection System 40 mL » In die Bestellung aufnehmen