| | | Per 10-inch Cartridge Filter |
|
| |
| Materials of Construction |
|
| |
| |
| |
| |
|
| | ≥1240 mbar (18 psig) nitrogen with 60//40 % IPA/water |
|
| Nitrogen Diffusion at 23 °c |
| | ≤10 mL/min @ 1.7 bar (25 psig) with water after IPA prewet |
|
| Maximum Differential Pressure, bar (psid) |
| | Forward: 5.5 (80) @ 25 °C; 3.5 (50) @ 80 °C; 0.35 (5) @ 135 °C. Reverse: 3.5 (50) @ 25 °C |
|
| | <0.5 EU/mL as determined by the LAL test |
|
| | Quantitative retention of 107 CFU/cm2 Brevundimonas diminuta ATCC® 19146 per ASTM methodology. |
|
| | 30 SIP cycles of 30 min @ 126 °C; 30 autoclave cycles of 60 min @ 126 °C |
|