Content Loading...
Content Loading...
Last Item Added: 0 Items
Content Loading...
» Close

Millistak+ CE Stacked Disc Filters

 

Description

Millistak+ clarification/prefiltration stacked disc filters have been specifically developed to meet the critical needs of the pharmaceutical and biotech industries, incorporating a broad range of controlled porosity graded density depth media.

Available media series satisfy most applications needs in the biopharmaceutical market where high concentrations of colloidal contaminant dictate the need for high surface area depth media with a positive charge. Within the CE series, a variety of grades enable the user to choose the filter best suited to his application. Media grades are differentiated by flow characteristics rather than by micron ratings. Nominal retention guidelines are provided but trials in customer fluids are recommended for selection of the optimum filter based on processing conditions. The CE series is suitable for coarse filtration in the 1 to 30 micron range.

Benefits

Monitored gradient density matrix assures consistent filtration performance
Filter matrix exhibits positive charge properties to enhance filtration performance
Broad range of media grades to assure optimal performance
Non-toxic
Media available to fit virtually any filter press

Extractables

Typical extractable levels have been determined by laboratory analysis utilizing a dynamic flow rinse procedure. Inorganic extractables are quantified by atomic absorption analytical techniques. The results are expressed as milligram per ft2 of media subsequent to the standard recommended flush of 100 L/m2 (10 L/ft2) of media surface area.

Metal mg/ft2 Media
Sodium 3.45 - 4.76
Calcium 2.56 - 2.74
Potassium 0.17 - 0.91
Magnesium 1.19 - 2.03
Iron <0.1
Lead <0.1
Aluminum <0.1
Titanium <0.1
Chromium <0.1
Manganese <0.1
Cobalt <0.1
Nickel <0.1
Copper <0.1
Zinc <0.1

Dimensions

Materials of Construction
Filter Media
Structural Components
Maximum Differential Pressure, bar (psid)
Bacterial Endotoxins
Component Material Toxicity Component materials meet the criteria of the USP <88> Reactivity Test for Class VI Plastics. These products meet the requirements of the USP <88> Safety Test, utilizing a 0.9% sodium chloride extraction.
Oxidizable Substances
Indirect Food Additive All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177–182.
Sterilization

Contact Us

We want to hear from you. Contact a specific department below or click "Suggestions and Feedback" to send your comments.