Cogent® μScale TFF System

Easy-to-use, semi-automated bench top TFF system for both micro-scale process development and everyday low-volume ultrafiltration/diafiltration work.

CogentMicroScale_unit-16[73042-ALL].jpg

The Cogent μScale tangential flow filtration (TFF) system is an easy-to-use, semi-automated bench top solution that has been designed to fully support TFF process development at the “micro-scale” using up to three Pellicon® 3 88 cm2 cassettes (264 cm2). It is also an excellent tool for streamlining everyday low volume ultrafiltration/concentration and diafiltration (UF/DF) work in the biopharmaceutical research environment.

With a low minimum working volume (16 mL*), the ability to operate at feed pressures up to 80 psi (5.5 bar) and low pulsation (≤3 psi), the Cogent μScale TFF system enables both scaling studies and low volume UF/DF work using Pellicon 3 88 cm2 TFF cassettes. It can also be configured to run up to three Pellicon XL 50 TFF devices (150 cm2), and is ideally suited for purifying and concentrating your monoclonal antibodies, recombinant proteins, vaccines, gene therapy constructs, blood serum products, and other cell derived components.
* Reference minimum working volume specification

       • Versatile system—ideally suited for both scaling studies and low volume UF/DF work
       • Enhanced productivity—User-configurable alarm set points and automated data acquisition
       • Easy-to-use—Intuitive, multilingual display and touch screen interface

Designed for Everyday Use

An intuitive, multilingual display and touch screen interface makes the Cogent μScale TFF system easy to operate, and the user-configurable alarm set-points and automated data acquisition enable you to be more productive. Time-stamped data for all operational parameters, including alarm and event history are automatically captured by the system and can be easily uploaded in a tab delimited/CSV file format directly to your PC, and imported into standard spreadsheet programs such as Microsoft® Excel®.

The semi-automated system can be run at either a fixed pump speed or at a set DeltaP via an automated control loop. Alarm set-points for feed and retentate pressure, DeltaP, TMP, and filtrate flow/weight (present only with filtrate weight scale option) include four settings that either “alert” you to changing conditions (Hi/Lo settings), or “shut down” the process (HiHi/LoLo settings) if desired. When an alarm condition is triggered, a message appears on the touch screen display. An audible alarm can also be activated. The system also includes an E-stop that will immediately shut down the process if needed.

With the optional filtrate weight scale, you can measure filtrate flow and weight. You also have the ability to automatically shut down your process when a target weight/product concentration has been achieved. The P&ID screen monitors all active parameters, including: pump speed, mixer speed, feed and retentate pressures, temperature, calculated feed flow rate, DeltaP, TMP, and calculated filtrate flow and weight (only with weight scale option), providing an easy way to monitor your process in real time. And through a separate trend screen you can quickly see how key process parameters have changed over the course of a run, facilitating process development.

The Cogent μScale TFF system includes a 1 L polypropylene tank with a removable vacuum seal lid that enables vacuum diafiltration/buffer exchange and/or fed batch processing of samples up to 5 L or more. Also included with the system is a filter holder for the Pellicon 3 88 cm2 cassettes, and a complete high pressure tubing assembly capable of running up to 80 psi (5.5 bar), enabling you to run at higher DeltaP and TMP settings.

       • Easily create accurate scale down models for process development, membrane screening and process characterization at the micro-scal   e – Enables you to do more with less product
       • Feed pressures up to 80 psi – Allows higher DeltaP and TMP processing
       • Robust design with minimal maintenance requirement

Real-world TFF Operations

CogentMicroScale_unit-16[73042-ALL].jpg

Optimized for Process Development and Research Applications

The Cogent μScale TFF system is designed to meet your real-world process development and low volume sample preparation requirements. This system will support all your TFF operations including fed batch, diafiltration and concentration. System set-up is quick and easy and the user interface and user-defined control parameters enable you to execute development work quickly, safely, reliably and reproducibly. The robust flow path supports flow rates from 17 mL/min to 330 mL/min at operating pressures up to 80 psig (5.5 bar) with very low pulsation. The system also has an extremely low minimum recirculation and hold up volume for low volume processing and maximum product recovery, and with a compact footprint, it is easy to use in any research or lab environment.

Cleanability

The fluid path is drainable and designed for Clean-in-Place (CIP) using industry standard cleaning agents. If cross contamination is a concern, the tubing assembly and one liter polypropylene tank assembly can be easily replaced in just a few minutes.

Automated Data Capture and Export

The Cogent μScale TFF system automatically captures time-stamped data for the following operational paramaters: Feed Pressure, Retentate Pressure, DeltaP, TMP, Feed Flow, Pump Speed, and Temperature. With the Weight Scale option, Filtrate Flow Rate and Filtrate Weight are captured as well. In addition, alarm history and event history (e.g., user login, calibration changes) are captured in separate time stamped files. These tab delimited/CSV files can then be manually or automatically uploaded directly to a PC for import into standard spreadsheet programs.

CogentMicroScalePID2-16[73043-ALL].jpg

Figure 1: Cogent μScale P&ID screen provides real-time monitoring of your TFF process

Specifications (return to top)

Supported TFF Devices
Pellicon 3 88 cm2 cassettesUp to 3 (88 cm to 264 cm2)
Pellicon XL 50 deviceUp to 3 (50 cm to 150 cm2)
Pellicon Cassette Holder Included with systemHolds up to three Pellicon 3 88 cm2 cassettes
Filtration Area, m20.005–0.0264
Volume, mL1000
Min Working Volume, mL16 (add 1.5 per Pellicon 3 88 cm2 cassette)
Hold-up Volume, mL< 3 (excluding cassette)
Process Temperature4–25
Flow Rate, L/min.02–0.33
Sensors
Feed and retentate pressure, bar (psi)0–5.5 (0–80)
Temperature0–50 °C (32–122 °F)
Retentate Control and Isolation ValvesManual
Weight Scale6 kg maximum capacity
Languages SupportedEnglish, French, German, Spanish, Italian, Chinese, and Japanese
Dimensions
Width, cm (in)41 (16.14)
Depth, cm (in)48 (18.89)
Height, cm (in)62 (24.40)
Weight, kg (lb)30 (66) with holder
Power Supply100–240 VAC, 50-60 Hz
Wetted Materials of Construction
Filter holder316 L stainless steel
TubingTygon® (PVC) and GORE™ STA-PURE® (platinum-cured silicone expanded PTFE) plastic
Luer fittingsPolypropylene
Pressure sensorsTitanium
Flow cellsPolysulfone
Stir barPTFE
O-ringsSilicone
Vent valvePolycarbonate
Wetted Materials
All polymer wetted materials of construction are USP Class VI tested.
Regulatory Information
The Cogent μScale system meets the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC, and is CE marked.


Guide d'achat  (retourner en haut de cette page)

Veuillez sélectionner 5 articles ou moins pour effectuer une comparaison.
Core System and Weight Scale

Comparer Référence Description  
CUP0300 Cogent μScale TFF system 100–240 VAC, 50–60 Hz » Demande d'informations
CUP0308 Filtrate weight scale » Demande d'informations
Spare Parts and Accessories

Comparer Référence Description  
CUP0301 1 L polypropylene tank subassembly » Ajouter à la commande
CUP0302 Tubing subassembly » Ajouter à la commande
CUP0303 Dual channel peristaltic pump head » Ajouter à la commande
CUP0304 Temperature/Pressure sensor subassembly » Ajouter à la commande
CUP0305 Pressure sensor subassembly » Ajouter à la commande
CUP0306 Retentate valve/manifold subassembly » Ajouter à la commande
CUP0307 Set of fuses for main switch » Ajouter à la commande
CMP0415 Batterie pour interface PLC » Ajouter à la commande
SLFG025LS Unité de filtration Millex-FG, 0,20 µm, PTFE hydrophobe, 25 mm, support en PVC, stérilisée à l'oxyde d'éthylène » Ajouter à la commande
XX42PMICR0 Pellicon 3 88 cm2 cassette filter holder » Ajouter à la commande
XXPXLSTND Support Pellicon XL » Ajouter à la commande
XXMULTIMN Kit de raccordement multiple » Ajouter à la commande