| | ASME compliant housings have been designed in accordance to the requirements of ASME Section VIII Division 1. |
|
| CE compliant housings have been designed and manufactured according to the essential requirements of the European Pressure Equipment Directive 97/23/EC. Series 3000 30-inch In-line and T-line housings are CE marked. |
|
| | The sealing materials supplied comply with the Title 21 Code of Federal Regulations, section 177.2600 for rubber compounds or 177.1550 for fluorocarbon resin, 177.1520 for olefin polymers. |
|
| | All seal materials comply with USP <88> Biological Reactivity Tests for Class IV plastics. |
|
| |
| | 10 bar (145 psig) at 25 °C (77 °F) |
|
| | 7 bar (100 psig) at 60 °C (140 °F) |
|
| | 6 bar (87 psig) at 80 °C (176 °F) |
|
| | 3.2 bar (46 psig) at 145 °C (293 °F) |
|
| Materials of Construction (Wetted Parts) |
| |
| All metal surfaces in contact with the product |
| | 316L (DIN 1.4404 and DIN 1.4435) stainless steel : (Code 0 spring is 316 stainless steel) |
|
| |
| Diaphragm valve membrane: |
| |
| Gasket and plunger valve seal: |
| |
| Optional gasket materials: |
| | EPDM, PTFE (Teflon polymer encapsulated Viton® fluoroelastomer) |
|
| |
| All T-line and In-line housing stainless steel wetted parts are electropolished Ra ≤ 0.5 µm internal, Ra ≤ 0.8 µm external. |
|
| All T-line and In-line housing stainless steel wetted parts are mechanically polished Ra ≤ 0.5 µm internal, Ra ≤ 0.8 µm external. |
|
| All T-line and In-line housing stainless steel wetted parts are electropolished Ra ≤ 0.4 µm internal, Ra ≤ 0.8 µm external. |
|
| All T-line and In-line housing stainless steel wetted parts are electropolished Ra ≤ 0.5 µm internal, Ra ≤ 0.8 µm external. |
|
| | Code 7, 0 and F (Housing type will determine cartridge code compatibility.) |
|
| | 4 in. sanitary flange with: |
|
| | 3-piece 304 stainless steel clamp standard on non-ASME compliant housings |
|
| | 2-piece bolted 304 stainless steel clamp standard on ASME stamped housings |
|