Content Loading...
Content Loading...
Last Item Added: 0 Items
Content Loading...
» Close

Lynx S2S Connector for sterile‑to‑sterile connection

Lynx S2S Connector for sterile‑to‑sterile connection



Description
The uniquely designed Lynx S2S connector is a single-use, single actuation, gamma- and autoclave-compatible disposable device for connecting sterilized fluid paths in biopharmaceutical processes.

The Lynx S2S connector is constructed of a female coupling and a male coupling. Once these two components are assembled together, the sterile fluid path is enabled. Once assembled, the two components cannot be disassembled, reducing the risk of sterility breach.



Fully actuated Lynx S2S Connector



Safe, Disposable Connectors
The Lynx S2S connector is disposable and intended for single-use, one-time actuation. There are no parts to clean-in-place, and the risk of contamination is reduced.


Quick and Easy Connectivity
A series of simple steps connects the two independently sealed fluid paths by joining the female coupling and the male coupling. Then by way of a slide, the sealing caps are moved out of the way. At this point, the female coupling and male coupling are connected and the two fluid paths are aligned, creating one continuous path that has not been exposed to outside contamination. This path is sterile when the female coupling and male coupling are assembled as part of a sealed assembly that has been properly sterilized by either gamma irradiation or autoclave.


No Special Capital Equipment Required
Once the couplings of the Lynx S2S connector have been gamma irradiated or autoclaved, the two sterilized assemblies can be connected in either a classified or non-classified environment. The unique design of the Lynx S2S connector does not require a specialized clean room or equipment to ensure a sterile connection.


Typical Applications
Ideally suited to a broad range of applications including sterile liquid transfer and microbiological sampling, the Lynx S2S connector provides the optimum solution for making secure, safe connections between two sterilized single-use disposable assemblies.

Sterile Liquid Transfer
The Lynx S2S connector can be integrated with assemblies that include single-use capsules, tubing, and flexible containers. Pre-sterilized by gamma irradiation or autoclave and ready to use, these assemblies are ideal for a wide range of liquid transfer applications and can be easily integrated into both the bulk production and final fill processes, ensuring the secure transfer of your valuable product. Best of all, the entire assembly is disposable.

Microbiological Sampling
Replace your current rubber septum or valve and bottle sampling techniques with a pre-sterilized disposable sampling system. A number of flexible sampling containers can be linked to each other via a Lynx S2S connector, and the entire assembly can be sterilized by gamma irradiation. This sterile connection to the sample point minimizes the risk of false positives. For instance, bioreactor sampling at multiple sites requires a large investment in capital equipment, is labor intensive and open to the risk of contamination. By utilizing the Lynx S2S connector for bioreactor sampling at multiple sites, the process is now secured, aseptic connections are eliminated and capital equipment costs and overhead labor are significantly reduced.



Specifications    (return to top)

Typical Flow Rate, L/min
71.9 @ 1.38 bar (20 psid) @ 25 °C (bi-directional)
Maximum Differential Pressure, bar (psid)
(actuated)
4.1 (60) @ 25 °C (bi-directional)
Materials of Construction
Connector
Polysulfone, USP Class VI, 21 CFR
O-rings
Silicone, USP Class VI, 21 CFR
Operating Temperature, °C
4–40
Fittings
Inlet - Female Connector
1/2 in Hose Barb to fit 0.43 in (10.9 mm) ID
Outlet - Male Connector
1/2 in Hose Barb to fit 0.43 in (10.9 mm) ID
Sterilization
Gamma compatible up to 45 kGy; Autoclave once for 30 minutes @ 130 °C. Do not steam in place.
Dimensions (envelope)
Height, mm
145.5
Width, mm
47
Length, mm
70
Toxicity
Classification of Plastics
Meets USP Class VI Biological Test for Plastics In-vivo <88> (wetted surfaces only)
Endotoxin
(LAL) pre- and post-gamma irradiation: ≤ 0.25 EU/mL
Particle Releasing
This product has been tested per USP <788> to ensure particulates >10 µm are <20/mL and particulates >25 µm are <2/mL.
Non-Fiber Releasing
Component materials meet the "non-fiber releasing" criteria as defined in 21 CFR 210.3 (b) (6).
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177–182.


Ordering Information  (return to top)

Select up to 5 products to compare them side by side

Compare Catalogue No. Description Sterility Qty/Pk  
SSCSHB2A01 Lynx S2S Connector Set Non-Sterile 1 Female, 1 Male » Add to Cart
SSCFHB2A12 Lynx S2S Female Couplings Non-Sterile 12 » Add to Cart
SSCFHB2A24 Lynx S2S Female Couplings Non-Sterile 24 » Add to Cart
SSCMHB2A12 Lynx S2S Male Couplings Non-Sterile 12 » Add to Cart
SSCMHB2A24 Lynx S2S Male Couplings Non-Sterile 24 » Add to Cart


Related Products  (return to top)
Mobius Disposable Solutions
Transform your process with Mobius flexible bioprocessing solutions from Millipore.
» Learn More...
Lynx® ST Connectors
Enables integration of steamable hard piped process equipment with disposable sterile fluid paths
» Learn More...