Millicell 24-well Cell Culture Plate

Millicell 24-well Cell Culture Plate

24-well assembly optimized for in vitro cell growth and user convenience


Ideal system for a range of cell-based assays
The Millicell 24-well Cell Culture Assembly is designed to support cell attachment, growth and differentiation for many cell applications. The plate assembly is used for cell growth as well as analysis and can be used manually or with automated cell seeding, feeding and washing systems.

Both a single-well feeding and 24-well receiver plate are available for use.



Patented cell-culture plate improves cell growth and analysis
The new 24-well Millicell Cell Culture plate assembly is designed for maximum user convenience and reliability. The plate features basolateral access ports at each well to allow for media addition without disassembling the cell culture plate and receiver tray. Additionally, the cell culture plate has feet to raise and protect the cell monolayer if the receiver tray is removed. Other features like raised well edges for improved tape sealing and large font labeling provide added user convenience.

The 24-well feeder tray incorporates a unique tear-drop well design to reduce the incidence of air bubbles that can form under the membrane during plate assembly. This feature ensures that cell monolayers are getting proper nutrients.

If a single-well tray is required, the Millicell assembly features a single-well tray with baffles to reduce media leakage and contamination.


Design improves cell culture assays and analysis




Performance

In-plate differentiation of embryonic stem cells and phenotype analysis

Neuron differentiation of embryonic stem cells in Millicell 24 1 µm PET filter plates. Murine embryonic stem cells were formed into suspended embryoid bodies (EBs) then transferred to 1 µm PET Millicell 24 for attachment and differentiation. Neural differentiation after retinoic acid treatment of attached EBs was confirmed by anti-neurofilament immunofluoresence. (Insert: Inverted phase contrast imaging through membrane of live EBs in media.)
Demonstrated transport and efflux studies with integral differentiated Caco-2 monolayers

Differentiation of 21-day Caco-2 monolayer by efflux pump expression. Anti-MDR1 immunohistochemistry confirms p-glycoprotein (MDR1) expression of Caco-2 monolayer grown in Millicell 24 with 1 µm PET membrane.


Ordering Information  (return to top)

Please select 5 or fewer Items to compare.

Compare Catalogue No. Description Components Qty/Pk  
PSHT010R1 Millicell-24 Cell Culture Insert Plate, polycarbonate, 0.4 µm 24-well cell culture plate, single-well feeder tray, 24-well feeder tray, lid 1 » Add to Cart
PSHT010R5* Millicell-24 Cell Culture Insert Plate, polycarbonate, 0.4 µm 24-well cell culture plate, single-well feeder tray, lid 5 » Add to Cart
PSST010R1 Millicell-24 Cell Culture Insert Plate, polycarbonate, 3.0 µm 24-well cell culture plate, single-well feeder tray, 24-well feeder tray, lid 1 » Add to Cart
PSST010R5* Millicell-24 Cell Culture Insert Plate, polycarbonate, 3.0 µm 24-well cell culture plate, 24-well feeder tray, lid 5 » Add to Cart
PSMT010R1 Millicell-24 Cell Culture Insert Plate, polycarbonate, 5.0 µm 24-well cell culture plate, single-well feeder tray, 24-well feeder tray, lid 1 » Add to Cart
PSMT010R5* Millicell-24 Cell Culture Insert Plate, polycarbonate, 5.0 µm 24-well cell culture plate, 24-well feeder tray, lid 5 » Add to Cart
PSET010R1 Millicell-24 Cell Culture Insert Plate, polycarbonate, 8.0 µm 24-well cell culture plate, single-well feeder tray, 24-well feeder tray, lid 1 » Add to Cart
PSET010R5* Millicell-24 Cell Culture Insert Plate, polycarbonate, 8.0 µm 24-well cell culture plate, 24-well feeder tray, lid 5 » Add to Cart
PSRP010R1 Millicell-24 Cell Culture Insert Plate, polyethylene terephthalate, 1.0 µm 24-well cell culture plate, single-well feeder tray, 24-well feeder tray, lid 1 » Add to Cart
PSRP010R5* Millicell-24 Cell Culture Insert Plate, polyethylene terephthalate, 1.0 µm 24-well cell culture plate, single-well feeder tray, lid 5 » Add to Cart
Accessories

Compare Catalogue No. Description Qty/Pk  
PSMW010R5 24-well Receiver Tray with Lid 5 » Add to Cart
PSSW010R5 Single-well Receiver Tray with Lid 5 » Add to Cart
*Bulk pack


Related Products  (return to top)
Milli-Q® Ultrapure Water Purification Systems
The standard for ultrapure water in the laboratory
Each of the five new Milli-Q systems is designed to specifically target contaminants detrimental to particular applications such as HPLC, molecular biology and ICP-MS. The systems incorporate a high precision resistivity monitor that records conductivity or resistivity (compensated or not at 25 °C), and also feature a built-in TOC monitor with a 1-999 ppb detection range for accurate analysis of organics.
» Learn More...
Millicell 24-well Cell Culture Plate
24-well assembly optimized for in vitro cell growth and user convenience
An ideal system for a range of cell-based assays using a patented cell-culture plate which improves cell growth and analysis.
» Learn More...