Amicon Ultra-4 and -15 Centrifugal Filter Units – 10,000 NMWL – For in vitro diagnostic use (CE)

 

  • Amicon Ultra-4* and -15* Centrifugal Filter Units are designed for in vitro diagnostic use and intended for concentrating serum, urine, cerebrospinal fluid and other body fluids prior to analysis.
  • The premier devices for concentrating 1 – 4mL or <15 mL
  • High recovery Ultracel regenerated cellulose membrane in a range of molecular weight cut-offs
  • High retentate recovery of >90%
  • Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes)
  • Heat-sealed membrane minimizes downstream extractables
  • 100% integrity tested for reliable performance
  • Convenient sample monitoring with translucent housing and volume gradations
  • Direct pipettor sample access eliminates processing step to recover concentrate
  • High concentration factors of 80–100X

* The Amicon Ultra-4 and Amicon Ultra-15 with Ultracel-10 membrane are CE marked.

Applications

  • Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms
  • Purification of macromolecular components found in tissue culture extracts or cell lysates
  • Concentration of dilute or pre-purified proteins from column eluents
  • Desalting and buffer exchange

Performance data - Amicon Ultra-4 Centrifugal Filter Unit

Typical Spin Times to Filtrate Volume

Spin 
conditions: 4000 xg swinging bucket rotor at 25 °C, 4 mL sample. <br 
/>3K, 10K: Cytochrome c (0.25 mg/mL); 30K, 
50K: BSA (1 mg/mL); 100K: IgG (1 mg/mL).

Spin conditions: 4000 xg swinging bucket rotor at 25 ° C, 4 mL sample.
3K, 10K: Cytochrome c (0.25 mg/mL); 30K, 50K: BSA (1 mg/mL); 100K: IgG (1 mg/mL).

Typical Protein Recovery

Membrane
NMWL, kDa
Protein Solute Protein Retentate
Volume, mL
Protein Retentate
Recovery, %
10 Cytochrome c, 12.4 kDa
(0.25 mg/mL)
0.20 95
4 mL starting volume in a fixed angle rotor at 7,500 x g at 25 °C. Spin times: 3K (30 min); 10 and 30K (10 min); 50K (5 min); 100K (15 min).

Performance data - Amicon Ultra-15 Centrifugal Filter Unit

Typical Spin Times to Filtrate Volume

Spin 
conditions: 4000 xg swinging bucket rotor at 25°C, 15 mL sample. <br 
/>3K, 10K: Cytochrome c (0.25 mg/mL); 30K, 
50K: BSA (1 mg/mL); 100K: IgG (1 mg/mL).

Spin conditions: 4000 xg swinging bucket rotor at 25° C, 15 mL sample.
3K, 10K: Cytochrome c (0.25 mg/mL); 30K, 50K: BSA (1 mg/mL); 100K: IgG (1 mg/mL).

Typical Protein Recovery

Membrane
NMWL, kDa
Protein Solute Protein Retentate
Volume, mL
Protein Retentate
Recovery, %
10 Cytochrome c, 12.4 kDa
(0.25 mg/mL)
0.24 93.03
15 mL starting volume in swinging bucket rotor at 4000 x g at 25 °C. Spin times: 3K (40 min); 10K and 100K (20 min); 30K (10 min); 50K (15 min).

Amicon Ultra filter units process 15 mL samples as fast as 10 15 minutes