Content Loading...
Content Loading...
Last Item Added: 0 Items
Content Loading...
» Close

Total Drug Analysis for Pharmacokinetic Studies

MultiScreen® Deep Well and MultiScreen Solvinert Filter Plates

Determining the concentration of drug in plasma or serum at various time points after administration is necessary to calculate the pharmacokinetics (PK) of a drug. PK, in turn, is an important component in the absorption, distribution, metabolism, and excretion (ADME) profile. Precise knowledge of ADME properties enables accurate determination of the proper drug dosage to maintain therapeutic drug levels without risking toxicity.

MultiScreen Deep Well Solvinert and MultiScreen Solvinert filter plates are pre-validated for in-plate precipitation of proteins from plasma or serum for total drug analysis. The plates enable fast, discreet and complete filtrate transfer to provide an automation-compatible platform for sample preparation prior to total drug analysis. Filtration with the Solvinert family of filter plates provides protein-free filtrate that is compatible with HPLC-MS or HPLC-UV analysis.

The MultiScreen Deep Well and MultiScreen Solvinert filter plates are robust and reliable platforms that generate reproducible results. Samples isolated from serum by protein precipitation and filtration through these plates are essentially protein-free and show high compound recovery and no interference from extractables.

Automation-compatible MultiScreen Deep Well Solvinert Filter Plates Yield Reproducible Results for Total Drug Determination

MH0404051-71[40104-EN].jpg

Warfarin was spiked into bovine serum followed by protein precipitation and filtration through MultiScreen Deep Well Solvinert filter plates. The assay was carried out manually and with complete automation. Drug concentrations in the filtrates were analyzed by LC-MS/MS and are compared. The linearity of results for both automated and manual methods (R2 values= .999) demonstrates that drug samples in serum can be reliably prepared manually or automated by precipitation and filtration in a MultiScreen Deep Well Solvinert filter plate. The high degree of linearity indicates that filtrates generated following this procedure allow accurate LC-MS/MS analysis across a wide concentration range.

High Performance Plate Designs

Automation-compatible MultiScreen Solvinert filter plates are available in 96-well deep well (2 mL) and standard (500 µL) formats. The one-piece plate designs incorporate rigid sidewalls to facilitate use with robotic gripper arms and provide space for barcode labels.

All MultiScreen Solvinert plate materials are selected for broad chemical compatibility and enable extended in-plate incubations with no leaking.

210104-71[8358-EN].jpg

Optimized for Drug Discovery and HPLC Sample Preparation

MultiScreen Solvinert filter plates – both deep well and standard – are optimized for drug discovery applications including total drug analysis, NCE cleavage from solid phase libraries, and sample preparation prior to HPLC or LC/MS/MS. The plates and membranes demonstrate low binding, low extractables and high recoveries. For chromatography separations, the MultiScreen Column Loader accessory can be used to create 96 minicolumns per plate.

MultiScreen Deep Well with hydrophobic membrane and prefilter is also well suited for total drug analysis in plasma by protein precipitation.

Hydrophilic and Hydrophobic PTFE Membranes Available

MultiScreen Solvinert filter plates are available with chemically-resistant hydrophilic and hydrophobic membranes to accommodate aqueous and non-aqueous samples. MultiScreen Deep Well Solvinert filter plates are also available with an optional pre-filter to use with highly particulate media. Both membranes are highly retentive (>99% retention of acid precipitated BSA).

For the broadest chemical resistance, hydrophobic PTFE membrane is recommended. Designed for extended sample incubation times and the lowest extractables, hydrophobic PTFE membrane is ideal for NCE cleavage and cleanup. It is also suitable for in-plate protein precipitation and sample recovery following in-plate compound cleavage from solids or beads. The plates are also used for peptide synthesis.

Hydrophilic PTFE membrane is optimized for low drug and protein binding with excellent throughput in typical aqueous and solvent sample preparation. High sample recoveries and low extractables provide for optimum analysis by HPLC and LC/MS/MS. The membrane is suitable for applications including natural product screening, aqueous solubility testing and total drug analysis.

Performance

High Recovery of Drug in Solvent-based Preparations

509031-71[6881-EN].jpg

Seven drugs were tested for percent recovery by acetonitrile plasma precipitation. Plasma stock samples (5 mL) were spiked with drug (100 µM stock and tritiated) to a final 5 µM drug concentration followed by 1-hour incubation. Protein was precipitated by the addition of acetonitrile (15 mL) and the solution was vortexed vigorously. For each drug a 300 µL aliquot of the supernatant was added to 8 wells per plate. The samples were filtered by vacuum filtration (12" Hg) and filtrates were collected. Percent recovery was determined by comparing an aliquot (100 µL) of filtrate to an aliquot of the precipitated stock (cpm filtrate/cpm precipitated stock). Results show superior drug recovery (>90%) for both hydrophilic and hydrophobic MultiScreen Solvinert plates. (The sample was pre-precipitated by the addition of CACN followed by vigorous mixing.) Equivalent results are seen with MultiScreen Deep Well Solvinert filter plates.

Broad Chemical Compatibility
ChemicalCompatibility
Acids
Acetic acid, glacialR
Hydrochloric acid (37%)R
Hydrochloric acid (1 N)R
Hydrochloric acid (6 N)R
Hydrochloric acid (conc.)R
Nitric acid (30%)R
Nitric acid (6 N)R
Nitric acid (conc.)R
Sulfuric acid (conc.)R
Trifluoroacetic acidR
Alcohols
Ethyl AlcoholR
Isopropyl AlcoholR
Methyl AlcoholR
Bases
Sodium Hydroxide (70%)R
Sodium Hydroxide (3 N)R
Sodium Hydroxide (conc.)R
Ammonium Hydroxide (conc.)R
Glycols
Glycerine (Glycerol)R
Aromatic Hydrocarbons
BenzeneR/TST*
Ketones
AcetoneR
CyclohexanoneR
Oils
Cottonseed oilR
Miscellaneous
Acetonitrile (ACN)R
DimethylformamideR
Dimethyl Sulfoxide (DMSO)R
DioxaneR
Formaldehyde (35%)R
HexaneR
Methylene ChlorideL
PyridineR
R = Recommended
L = Limited Recommendation
NR = Not Recommended
TST = Testing Recommended

Note: The storage lid does not have the same solvent resistance properties as the filter plate and can be damaged by exposure to some solvent vapors.
*Dioxane, Hexane and Benzene are not recommended for use in Deep Well plates

The data presented in this chart are a compilation of testing by Millipore with certain chemicals and manufacturers' compatibility recommendations. These data are intended to provide expected results when filtration devices are exposed to chemicals for 48 hours at 25 °C (77 °F), unless otherwise noted.

Extended Incubation Times with No Leaking
Solution 24-hour Incubation Performance
Hydrophilic
PTFE Membrane
Hydrophobic
Milli-Q 18 M WaterRR
EtOH, 100%RR
MeOH, 100%RR
MeCl2NRR
DMSO/PBS (5%/95% v/v)RR
ACN, 100%RR
ACN/H2O (75%/25% v/v)RR
TFA/ACN (80%/20% v/v)NRR
DMSO, 100%RR
DMF, 100%RR
NaOH, 1.75NRR
R = Yes
NR = Not recommended. Some wells exhibited partial or complete drip out in 24 hour testing. May be compatible for shorter incubation times.

Table 2. MultiScreen Solvinert Filter Plates are designed to support extended incubations. This solvent compatibility table shows results reported for 200 µL of liquid with 24 hours incubation at room temperature.

Specifications (return to top)

Filter PlatesMultiScreen Deep Well SolvinertMultiScreen Solvinert
Sample Volume per Well
Recommended, mL50 µL - 1.8 mL50 µL - 0.45 mL
Maximum, mL0.5
Filtration Parameters
Relative Centrifugal ForceMaximum 3,000 x g
Maximum Vacuum, mm Hg (in. Hg)610 (24)610 (24)
Materials
Base PlatePolyolefin copolymer
MembraneHydrophilic PTFE
orMDRP N04 10Hydrophobic PTFE
PrefilterPolypropylene (optional)N/A
Dimensions
Membrane Area, cm20.28
Plate Length, mm128
Plate Width, mm85.5
Plate Depth, mm14.6


Ordering Information  (return to top)

Select up to 5 products to compare them side by side
MultiScreen Deep Well Solvinert Filter Plates

Compare Catalogue No. Filter Material Qty/Pk  
MDRLN0410 Hydrophilic PTFE 10 » Add to Cart
MDRPN0410 Hydrophobic PTFE 10 » Add to Cart
MultiScreen Deep Well Solvinert Filter Plates with prefilter

Compare Catalogue No. Filter Material Qty/Pk  
MDRPNP410 Hydrophobic PTFE 10 » Add to Cart
MultiScreen Solvinert Filter Plates

Compare Catalogue No. Filter Material Qty/Pk  
MSRLN0410 Hydrophilic PTFE 10 » Add to Cart
MSRLN0450 Hydrophilic PTFE 50 » Add to Cart
MSRPN0410 Hydrophobic PTFE 10 » Add to Cart
MSRPN0450 Hydrophobic PTFE 50 » Add to Cart
Accessories

Compare Catalogue No. Description Qty/Pk  
MSVMHTS00 MultiScreenHTS Vacuum Manifold 1 » Add to Cart
MSVMHTS0D Deep Well Collar 1 » Add to Cart
MSVMHTS0H Collar Holder, for automation 1 » Add to Cart


Related Products  (return to top)
MultiScreenHTS Vacuum Manifold
MultiScreen vacuum manifolds have been developed for all vacuum filtration applications using MultiScreenHTS and MultiScreen filter plates. Manifold components are resistant to solvents and suitable for use with automated or manual protocols.
» Learn More...
Centrifugal and Chromatography Accessories
MultiScreen Column Loaders let you combine the cost savings of bulk media with the convenience of 96-well filtration plates. Ideal for economical high-throughput bioassays, four different sizes cover a wide range of assays. All 96 wells are loaded simultaneously and uniformly, eliminating the need to pipette slurries or gels or the need to use expensive prepacked columns or kits.
» Learn More...