Cell Analysis
Cell analysis techniques improve our basic understanding of cellular mechanisms and help identify the proteins and pathways involved in disease.
We provide you one of the broadest offerings of multiwell filter plates, antibodies, and other reagents for studying cells.
In the section, you will find an overview of our products for immunocytochemistry/immunohistochemistry, western blotting, and immunoprecipitation. You will also find protocols for the detection of BrdU and free phosphates, as well as protocols for ELISA assays and cell staining. These procedures represent only a handful of the many techniques that we support.
Western Blotting
Since its introduction in 1979 (Towbin et al., 1979), protein blotting has become a routine tool in research laboratories. It is traditionally used to detect low amounts of proteins in complex samples or to monitor protein expression and purification.
»Learn More...
Immunoprecipitation
It is possible to use antibody-antigen precipitation (immuoprecipitation) to isolate a specific antigen from complex protein mixtures such as cell or tissue lysates. Immunoprecipitation has proven to be an invaluable investigational tool that is routinely employed by many laboratories to ascertain critical information regarding a given antigen. These include small scale antigen purification for functional studies, N-terminal sequence analysis, investigation of protein-protein interactions, and the determination of the relative abundance and stoichiometric distribution of the antigen within a cell or tissue, among other things.
»Learn More...
Immunostaining (ICC/IHC)
Immunohistochemistry/immunocytochemistry is the demonstration of a tissue or cellular constituent in situ by detecting specific antibody-antigen interactions where the antibody has been tagged with a visible label. The visual marker may be a fluorescent dye, colloidal metal, hapten, radioactive marker or an enzyme.
»Learn More...
Immunocytochemistry General Protocol
Immunocytochemistry (ICC) by definition is the demonstration of a tissue constituent in situ by detecting specific antibody-antigen interactions where the antibody has been tagged with a visible label. The visual marker may be a fluorescent dye, colloidal metal, hapten, radioactive marker or more commonly, an enzyme for light microscopy.
»Learn More...
BrdU Labeling & Immunocytochemistry Protocol
Adherent or non-adherent cells can be labeled. Usually the labeling is done for a short period, such as two hours as shown in this example. However one can label overnight or even days depending upon the experiment.
»Learn More...
Flow Cytometry
Flow Cytometry is a powerful multi-parametric single cell analysis platform with wide applications in basic research and clinical medicine for the diagnosis, isolation and study of specific cell types and disease conditions.Donec accumsan, purus ut viverra pharetra, augue tellus vehicula orci, eget consectetuer neque. Purification.»Learn More...
ELISA Procedures
Enzyme-linked Immunosorbent Assays (ELISAs) combine the specificity of antibodies with the sensitivity of simple enzyme assays, by using antibodies or antigens coupled to an easily assayed enzyme that possesses a high turnover number. ELISAs can provide a useful measurement of antigen or antibody concentration.
»Learn More...
General Protocol for the Sandwich ELISA Method
Step-by-step procedures...
»Learn More...
General Protocol for the Competitive ELISA Method
Step-by-step procedures...
»Learn More...
Elispot
MultiScreenHTS filter plates are available with validated Immobilon®-P (PVDF) membrane for superior results. Plates with HA (mixed cellulose esters) are also available. Both provide membranes with dense uniform pore structure to promote antibody binding and increase sensitivity for better, sharper spot definition.
»Learn More...
Elispot Protocols
The Elispot (Enzyme Linked Immuno-Spot) assay provides an effective method of measuring the antibody or cytokine production of immune cells on the single cell level. The popularity of this assay has seen resurgence in recent years as researchers attempt to gain a better understanding of immune responses in a variety of applications.
»Learn More...
Cell Lysates and Tissue Extracts for Malachite Green Protocol
Cell lysates and tissue extracts contain millimolar concentrations of free phosphate that will interfere with the phosphatase assay. In addition, ATP at high concentrations can increase the background and lead to phosphorylation by contaminating kinases. It is therefore necessary to eliminate these components from samples by running samples over a Sephadex® G-25 resin (GE Healthcare Biosciences).
»Learn More...
Product News & Releases
- Millipore Issues New Laboratory Filtration Product Guide
- Millipore Launches Progenitor Cell-Enriched Primary Human Epithelial Cell Cultures
- Millipore Launches MILLIPLEX™ MAP
- Millipore Adds to Stem Cell Tested Initiative
Featured Products
- ENStem-A Human Neural Progenitors
- ReNcell Human Neural Progenitors
- HEScGRO Human Embryonic Stem Cell Medium
- Cardiac Stem Cell Isolation Kit
- Mouse Embryonic Stem Cell Neurogenesis Assay
- Cellntec Products for Bladder Research
- Steriflip Filter Units
- Stem Cell Tested Filter Units
- Epidermal Growth Factors

