Vaccines
Millipore recommends running small-scale trials for capacity and throughput screening. This table provides details on process development devices for recommended filters and alternatives since the ideal solution will vary based on each fluid stream. The following order table is for recommended devices only.
Mammalian Cell
| Prostak MF Open-Channel 2-stack Modules |
| Durapore 0.22 ìm membrane | 0.17 m | PSGVAG021 |
| Millistak+ Mini Capsules |
| Grade B1HC | 13.8 cm2 | MB1HC23HH3 |
| Grade C0HC | 13.8 cm2 | MC0HC23HH3 |
| Grade D0HC | 13.8 cm2 | MD0HC23HH3 |
| Opticap XL1 Capsules |
| Clarigard 0.3 ìm media | 1-inch* | K003A51TT1 |
| OptiScale Capsules |
| Double-layer Milligard SS 0.5 ìm + 0.2 ìm membrane | 13.8 cm2 | SVSSA47FF3 |
| Durapore 0.22 ìm membrane | 13.8 cm2 | SVGLA47FF3 |
| Double-layer Millipore Express SHC 0.5 ìm + 0.2 ìm membrane | 13.8 cm2 | SHGEA47FF3 |
| Pellicon 2 C Screen Mini-Cassettes |
| Ultracel PLC C Screen 100 kD membrane | 0.1 m2 | P2C100C01 |
| Ultracel PLC C Screen 300 kD membrane | 0.1 m2 | P2C300C01 |
| Ultracel PLC C Screen 1,000 kD membrane | 0.1 m2 | P2C01MC01 |
Viral Vectors
| Millistak+ Mini Devices |
|
| 23 cm2 | M40CE23HH3 |
|
| 23 cm2 | M45CE23HH3 |
| Grade CE50 | 23 cm2 | M50CE23HH3 |
| Evaluation Kit with OptiScale-25 Capsules** |
| Viresolve NFP membrane | 3.5 cm2 | SVPVA25NB9 |
| OptiScale-40 Devices |
| Viresolve Prefilter | 5 cm2 | SSPVA40NB9 |
| OptiScale Capsules |
| Durapore 0.22 ìm membrane | 13.8 cm2 | SVGLA47FF3 |
| Durapore 0.45 ìm membrane (order with 0.5 ìm prefilter SW06A47FF3) | 13.8 cm2 | SVHLA47FF3 |
| Pellicon 2 V Screen Mini-Cassettes |
Ultracel PLC 300 kD membrane
| 0.1 m2 | SVPVA25NB9 |
Plasmid DNA
| Opticap XL1 Capsules |
|
| 1-inch* | KR10A51TT1 |
| Clarigard 0.5 ìm media | 1-inch* | K005A51TT1 |
| OptiScale Capsules |
| Double-layer Millipore Express SHC membrane | 13.8 cm2 | SHGEA47FF3 |
| Pellicon 2 V Screen Mini-Cassettes |
| Ultracel PLC 30 kD membrane | 0.1 m2 | P2C030V01 |
| Ultracel PLC 100 kD membrane | 0.1 m2 | P2C100V01 |
| Pellicon 2 C Screen Mini-Cassettes |
| Ultracel PLC 30 kD membrane | 0.1 m2 | P2C030V01 |
| Ultracel PLC 100 kD membrane | 0.1 m2 | P2C100V01 |
Conjugates
| Pellicon V Screen Mini-Cassettess |
Ultracel PLC 30 kD membrane
| 0.1 m2 | P2C030V01 |
Ultracel PLC 100 kD membrane
| 0.1 m2 | P2C100V01 |
Ultracel PLC 300 kD membrane
| 0.1 m2 | P2C300V01 |
| Ultracel PLC 1,000 kD membrane | 0.1 m2 | P2C01MV01 |
| Pellicon 2 C Screen Mini-Cassettes |
| Ultracel PLC 30 kD membrane | 0.1 m2 | P2C030C01 |
| Ultracel PLC 100 kD membrane | 0.1 m2 | P2C100C01 |
| Ultracel PLC 300 kD membrane | 0.1 m2 | P2C300C01 |
| Ultracel PLC 1,000 kD membrane | 0.1 m2 | P2C01MC01 |
| Prostak UF 4-stack Modules |
| Ultracel PL 5 kD membrane | 0.39 m2 | PSLCSP041 |
| Ultracel PL 10 kD membrane | 0.39 m2 | PSLGSP041 |
| Ultracel PL 30 kD membrane | 0.39 m2 | PSLTSP041 |
| OptiScale Devices |
| Durapore 0.22 ìm membrane | 13.8 cm2 | SVGLA47FF3 |
Multilayer Durapore 0.45 ìm + 0.22 ìm membrane
| 13.8 cm2 | SHGLA47FF3 |
Polysaccharides
| Prostak MF Open-Channel 2-stack Modules |
Durapore 0.22 ìm membrane
| 0.17 m2 | PSGVAG021 |
Durapore 0.45 ìm membrane
| 0.17 m2 | PSHVAG021 |
| Durapore 0.65 ìm membrane | 0.17 m2 | PSDVAG021 |
| OptiScale Devices |
| Double-layer Milligard LS 0.5 ìm + 0.2 ìm media | 13.8 cm2 | SWLSA47FF3 |
| Double-layer Millipore Express SHC membrane | 13.8 cm2 | SHGEA47FF3 |
| Durapore 0.22 ìm membrane | 13.8 cm2 | SVGLA47FF3 |
| Multilayer Durapore 0.45 ìm + 0.22 ìm membrane | 13.8 cm2 | SHGLA47FF3 |
| Pellicon 2 C Screen Mini-Cassettes |
| Ultracel PLC 30 kD membrane | 0.1 m2 | P2C030C01 |
| Ultracel PLC 100 kD membrane | 0.1 m2 | P2C100C01 |
| Millistak+ Mini-Capsules |
| Grade B1HC | 23 cm2 | MB1HC23HH3 |
*Filter element size
**Viresolve membranes are available in an Evaluation Kit containing 9 OptiScale-25 Capsules, 3 each of 3 membrane lots, and are ideal for scale-up and scale down studies